Disposable Infusion Pump

Instrument Classification: Class II
MOQ: 1000PCS
Material: PVC
Package: Individual PE Bag
Certificate: CE/ISO13485
Transport Package: Paper Carton
Samples:
US$ 5/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
HPL-244
Specification
100ml
Trademark
hiprove
Origin
China
HS Code
9018390000
Production Capacity
100000 PCS/Month

Product Description

disposable CBI infusion pump
volume 60ml,100ml,150ml, 200ml,275ml
flow velocity:0.5ml/h,1.0ml/h,2.0ml/h,3.0ml/h,4.0ml/h,5.0ml/h,6.0ml/h
CE certificate.
EO sterile
Brief Introduction:
This medical device is for clinical ease-pain treatment,relieve or lenitive pain.
It uses the flexibility of the silicone reservoir to allow for a constant minimal drop control through the capacity catheter, in
order to guarantee a safe efficient continuous ease-pain infusion.

Construction:
The device is composed of:
1. Single valve add-medicine set
2. Elasticity bursa stocker set
3. Medicine liquid filter
4. Bounds flux set
5. Self-control infusion( it could be without)
6. Pipeline and conical connectors
Apply Scope:

This product is used for continuous minimal infusion clinical treatment.

Use instruction:
1. Take out the infusion pump from the sterile package
2. Remove the cap from the add-medicine inlet, clip the stopper closed, infuse the prepared medicine by syringe into the liquid
bursa stocker.
3. When adding medicine, please make sure there is no air in syringes, then infuse the medicine. if there is air in bursa, you can
turn round and take out all the air( as the bursa can exhaust itself; if there is few air, it can exclude after 1-2 hours later).
4. After medicine has been added, open the clip, and press the self-control button(CPA) 1-2 times, for expedite the flow into the
pipeline; when the medicine flows from the end, clip the stopper and screw the cover for use next time.
5. The PCA button is the function button that the patient can use it to control the additional medicine when in continuous
medicine infusion position. by pressing the PCA button, the patient can add a limited quantity of medicine in respect with
doctor's instruction, as he needs.
6. The flux will be a little faster ( within the standrad scope) during the 1-2 first hours of use; that is due to the physical
characteristic of the silicone bursa.
7. The standrad flow and infusion time has been established for: distilled water as medium, inside job temperature as the standrad
temperature; the differetn medicine density, medicine viscosity, operation temperature and the bursa place etc....whill will

effect the flow in a range of sround 10% differences.