Good Quality Electric Centrifuge 80-2 for Lab Use

Qingdao Hiprove Medical Technologies Co., Ltd.
  • Audited Supplier
  • 11 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Wide Speed Range: Turn speed adjustable from 500 to 4000 revolutions per minute for various lab needs.
  • Flexible Timing: Timing range of 1-60 minutes or continuous operation mode available.
  • High RCF: Maximum relative centrifugal force reaches 2350g for effective separation.
  • Standard Capacity: Centrifugal capacity supports 12 tubes of 12ml each for batch processing.
  • Versatile Applications: Suitable for collecting cells, separating plasma, DNA, proteins, and viruses.
  • Safety Features: Strict safety protocols including cover lock and professional repair requirements.
  • Low Power Consumption: Motor power is 40W, operating on AC 220V 50Hz power supply.
  • Easy Maintenance: Carbon brush replacement instructions provided to extend instrument life.

Product Images of Good Quality Electric Centrifuge 80-2 for Lab Use

Good Quality Electric Centrifuge 80-2 for Lab Use pictures & photos
Good Quality Electric Centrifuge 80-2 for Lab Use
Good Quality Electric Centrifuge 80-2 for Lab Use pictures & photos
Good Quality Electric Centrifuge 80-2 for Lab Use
Good Quality Electric Centrifuge 80-2 for Lab Use pictures & photos
Good Quality Electric Centrifuge 80-2 for Lab Use
Good Quality Electric Centrifuge 80-2 for Lab Use pictures & photos
Good Quality Electric Centrifuge 80-2 for Lab Use
Good Quality Electric Centrifuge 80-2 for Lab Use pictures & photos
Good Quality Electric Centrifuge 80-2 for Lab Use
Good Quality Electric Centrifuge 80-2 for Lab Use pictures & photos
Good Quality Electric Centrifuge 80-2 for Lab Use
  • Good Quality Electric Centrifuge 80-2 for Lab Use
    Good Quality Electric Centrifuge 80-2 for Lab Use
  • Good Quality Electric Centrifuge 80-2 for Lab Use
    Good Quality Electric Centrifuge 80-2 for Lab Use
  • Good Quality Electric Centrifuge 80-2 for Lab Use
    Good Quality Electric Centrifuge 80-2 for Lab Use
  • Good Quality Electric Centrifuge 80-2 for Lab Use
    Good Quality Electric Centrifuge 80-2 for Lab Use
  • Good Quality Electric Centrifuge 80-2 for Lab Use
    Good Quality Electric Centrifuge 80-2 for Lab Use
  • Good Quality Electric Centrifuge 80-2 for Lab Use
    Good Quality Electric Centrifuge 80-2 for Lab Use

Find Similar Products

Product Description

electric centrifuge 80-2 for laboratory use

the main technical parameters:
1  use the power supply ,AC 220V 50HZ
2 motor power ,40w
3 turn speed .500-4000 revolutions per minute
4 centrifugal capacity 12ml×12
5 timing range .1-60min or normally open
6 RCF.2350×g
MOQ: 100 pcs.


A  Summary:
Centrifugal separation technology is a new technology developed according to the state of particles in a practical centrifuge. Particles of different densities, sizes, and shapes settle in centrifugation at different speeds, so a roughly spherical, heterogeneous mixture can be separated by centrifugation. The centrifuge is to separate a large number of substances without studying biochemistry. For example, collect cells, separate plasma, separate DNA and proteins from these purified formulations, and isolate viruses and large - scale e. coli.
B  Main technical parameters:
1: use the power supply. Ac 220 v50hz                 
2: motor power. 60 w                                   
3: turn speed. 500-4000 revolutions per minute          
4: centrifugal capacity. 20 ml x 12
5: timing range. 1-60 min or normally open
6: RCF. 2350 xg
C: use safety instructions
Remember to follow the following safety precautions when using this product:
1.Read all instructions.
2.The electrical rated parameters of the socket provided by the user shall not be less than the electrical rated parameters of the machine and have good grounding measures.
3.When replacing the fuse, pull the power plug out of the socket.
4.After the instrument breaks down, it should be repaired by professionals. The use of accessories not recommended by the manufacturer will cause certain quality problems.
  1. When the rotor of the centrifuge is running, it is strictly forbidden to open the cover, and the rotor must be stopped completely. To open the cover to remove the centrifugal tube.
  2. The instrument is strictly prohibited to move during operation.
  3. All kinds of liquid or other sundries are strictly forbidden to enter the working room of the centrifuge, otherwise the main engine will be damaged.
  4. Instruments in use, should be looked after.
9.  The power should be cut off before cleaning the machine.
10. The instrument should be used in a dry environment to avoid accidents caused by damp.


D: instructions
  1. The instrument should be placed on a stable work table, the environment should be clean and tidy, temperature, humidity and good ventilation.
  2. Set the speed adjustment knob to the minimum position before using the instrument.
The centrifugal tubes which need to be separated are inserted into the centrifugal tubes respectively. In order to make the instrument work smoothly. Avoid large vibrations. The material added to each centrifuge tube must be basically equal. And inserted symmetrically into the centrifugal tube. and then closed the cover plate.
4.  Choose timing, the timing knob transferred to the "timing" or "ON" position.
5.  Turn on the power supply and slowly adjust the speed control knob to the required speed.
6.  Before the shutdown, the speed control knob must be placed in the minimum position to turn off the power switch and cut off the power supply
E:maintaining
  1. Use the instrument correctly and pay attention to the maintenance of the instrument, make it in good working condition, can extend the service life of the instrument.
  1. The instrument should be checked regularly three months during continuous operation:Check whether there is water drop, dirt, etc. falling into the motor and control assembly, check carbon brush, fuse, control assembly and fastening screw,After using for a period of time, if the speed of the centrifuge becomes slow, please check the carbon brush and replace it in time.(Replacement method: cut off the power, open the bottom plate, remove the circular plastic cap near the bottom of the motor, and replace the old carbon brush with the new one)
  2. After long-term use of the instrument, natural wear is normal. If the machine is found to have abnormal noise, bearing wear of the motor, failure of electronic control components and other faults after one year of use, the company will continue to provide quality services and provide assistance

Good Quality Electric Centrifuge 80-2 for Lab Use

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR235261". Items marked "verified" are certified.

Watch Video
Watch Video
Qingdao Hiprove Medical Technologies Co., Ltd.
Qingdao Hiprove Medical Technologies Co., Ltd.
Qingdao Hiprove Medical Technologies Co., Ltd.
Qingdao Hiprove Medical Technologies Co., Ltd.
Qingdao Hiprove Medical Technologies Co., Ltd.
Qingdao Hiprove Medical Technologies Co., Ltd.
Qingdao Hiprove Medical Technologies Co., Ltd.
Qingdao Hiprove Medical Technologies Co., Ltd.

About Our Factory & Business Background

Address
No. 237 Wannianquan Road, Qingdao, Shandong, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, CFR, CIF, DAT, FAS, DDP, DAP, CIP, CPT, FCA, EXW, Others
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
QingDao, ShangHai

Our Production Capability & Technical Expertise

Main Products
Alcohol Swabs, Blood Mixer, Blood Collection Tube, Infusion Sets, Syringe, Blood Transfusion Sets, Bandage, Infusion Pump, Gauze Rolls, Bottle Preforms

Our Industry Experience & Global Business Record

Export Year
2005-01-17
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What are the main technical parameters of the centrifuge?
Power: AC 220V 50Hz; Motor Power: 40W; Speed: 500-4000 r/min; Capacity: 12ml*12; Time: 1-60min; RCF: 2350g.
What is the minimum order quantity (MOQ)?
The MOQ is 100 pieces.
What are the safety precautions during operation?
Do not open the cover while the rotor is running; ensure good grounding; do not move the instrument during operation; keep liquids out of the working room.
How should the centrifuge be maintained?
Check for dirt or water drops every three months. If speed slows, check and replace carbon brushes. The company provides assistance for faults after one year.
What are the common applications for this centrifuge?
It is used for collecting cells, separating plasma, isolating DNA and proteins, and separating viruses and large-scale E. coli.
What is the lead time for delivery?
The average lead time is within 15 workdays for both peak and off-season periods.
What payment terms are accepted?
Accepted payment methods include LC, T/T, D/P, PayPal, Western Union, Small-amount payment, and Money Gram.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Product Categories

Product Catalogs