Good Quality Electric Centrifuge 80-1 for Lab Use

Product Details
Customization: Available
Function: Prp Treatment
Max Rcf: 1795 Xg
Still deciding? Get samples of US$ 40/set
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation
Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
GMP, BSCI, ISO 13485, FSC
OEM/ODM Availability
Yes
  • Good Quality Electric Centrifuge 80-1 for Lab Use
  • Good Quality Electric Centrifuge 80-1 for Lab Use
  • Good Quality Electric Centrifuge 80-1 for Lab Use
  • Good Quality Electric Centrifuge 80-1 for Lab Use
  • Good Quality Electric Centrifuge 80-1 for Lab Use
  • Good Quality Electric Centrifuge 80-1 for Lab Use
Find Similar Products

Basic Info.

Model NO.
HPL-067
Power Supply
AC 220V/110V 50Hz/60Hz
Product Name
Good Quality Electric Centrifuge 80-1 for Lab Use
Transport Package
Paper Carton
Specification
80-1
Trademark
hiprove
Origin
China
HS Code
84210000
Production Capacity
1000 Set/Month

Product Description

Good Quality Electric Centrifuge 80-1 for Lab Use

the main technical parameters:
1  use the power supply AC 220V/110v50HZ/60/hz
2  motor power:25w
3   turn speed. 50-4000 revolutions per minute
4  centrifugal capacity 20ml×6
5  timing range 1-60min or normally open
6  RCF .1795×g


A  Summary:
Centrifugal separation technology is a new technology developed according to the state of particles in a practical centrifuge. Particles of different densities, sizes, and shapes settle in centrifugation at different speeds, so a roughly spherical, heterogeneous mixture can be separated by centrifugation. The centrifuge is to separate a large number of substances without studying biochemistry. For example, collect cells, separate plasma, separate DNA and proteins from these purified formulations, and isolate viruses and large - scale e. coli.
B  Main technical parameters:
1: use the power supply. Ac 220 v50hz                 
2: motor power. 25 w                                   
3: turn speed. 500-4000 revolutions per minute          
4: centrifugal capacity. 20 ml x 6
5: timing range. 1-60 min or normally open
6: RCF. 1790 xg
C: use safety instructions
Remember to follow the following safety precautions when using this product:
1.Read all instructions.
2.The electrical rated parameters of the socket provided by the user shall not be less than the electrical rated parameters of the machine and have good grounding measures.
3.When replacing the fuse, pull the power plug out of the socket.
4.After the instrument breaks down, it should be repaired by professionals. The use of accessories not recommended by the manufacturer will cause certain quality problems.
  1. When the rotor of the centrifuge is running, it is strictly forbidden to open the cover, and the rotor must be stopped completely. To open the cover to remove the centrifugal
tube.
  1. The instrument is strictly prohibited to move during operation.
  2. All kinds of liquid or other sundries are strictly forbidden to enter the working room of the centrifuge, otherwise the main engine will be damaged.
  3. Instruments in use, should be looked after.
9.  The power should be cut off before cleaning the machine.
10. The instrument should be used in a dry environment to avoid accidents caused by damp.


D: instructions
  1. The instrument should be placed on a stable work table, the environment should be clean and tidy, temperature, humidity and good ventilation.
  2. Set the speed adjustment knob to the minimum position before using the instrument.
The centrifugal tubes which need to be separated are inserted into the centrifugal tubes respectively. In order to make the instrument work smoothly. Avoid large vibrations. The material added to each centrifuge tube must be basically equal. And inserted symmetrically into the centrifugal tube. and then closed the cover plate.
4.  Choose timing, the timing knob transferred to the "timing" or "ON" position.
5.  Turn on the power supply and slowly adjust the speed control knob to the required speed.
6.  Before the shutdown, the speed control knob must be placed in the minimum position to turn off the power switch and cut off the power supply
E:maintaining
  1. Use the instrument correctly and pay attention to the maintenance of the instrument, make it in good working condition, can extend the service life of the instrument.
  1. The instrument should be checked regularly three months during continuous operation:Check whether there is water drop, dirt, etc. falling into the motor and control assembly, check carbon brush, fuse, control assembly and fastening screw,After using for a period of time, if the speed of the centrifuge becomes slow, please check the carbon brush and replace it in time.(Replacement method: cut off the power, open the bottom plate, remove the circular plastic cap near the bottom of the motor, and replace the old carbon brush with the new one)
  2. After long-term use of the instrument, natural wear is normal. If the machine is found to have abnormal noise, bearing wear of the motor, failure of electronic control components and other faults after one year of use, the company will continue to provide quality services and provide assistance
Product name Good Quality Electric Centrifuge 80-1 for Lab Use
MOQ 20 pcs
OEM available



Good Quality Electric Centrifuge 80-1 for Lab Use

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier